Energy Management
Power Analyzer Power Transducer Power Transducer
Types WM22-DIN SPT-90 PQT-90
162.5 x 90 x 63
MODULAR
3-phase power analyzer.
Direct connection up to 90 A.
Back-lighted LCD display.
4 x 3
1
/2 dgt istantaneous
variables read out,
7
1
/2 dgt energy read out.
Measurement of system
and phase variables.
Measurement of THD.
100VL-L[AV6], 208VL-L[AV4],
400V
L-L[AV5],660VL-L[AV7]
5(10) AAC;
208V
L-L[AV0],400VL-L[AV1],
660VL-L[AV3] 20(90) AAC;
Class 1: (EN61036)
Class 2: (EN61268)
Dual pulse output
module (NPN trans.)[O]
1 alarm output module [O]
(NPN tr) 30 VDC//100 mA Max.
1 analogue output :
0 to 20 mADC [A1],
or 0 to 10 VDC [V1]
RS422/485 serial port
[SO]
Self power supply:
400VAC 208VAC VL-L
Auxiliary power supply:
230[D], 115[C], 48[B],
24 [A]VAC 18 to 60
VDC [4]
CE
See pag. 102
Dimensions
(mm) H x W x D
Description
Function
Input Specifications
Range code
Accuracy
Active energy
Reactive energy
Sampling Rate
Output Specifications
Out 1 (Pulse)
Out 1 (Alarm)
Out 2 (Analogue)
Out 2
(Serial communication)
Inputs
Options
General Specifications
Power supply
Approvals/Marks
Ordering References
90 x 90 x 138
MODULAR
3-phase transducer. 1-phase,
3-phase 3 or 4 wires.
Measurement of: W, Wdmd, VA,
var, PF, Wh, VAh, varh, V
L-L sys,
VL1-N, VL2-N, VL3-N, Hz
.
Programming unit or
programming software
100VAC 1A[AV1]; 100VAC
5A[AV3]; 433VAC 1A
[AV4]; 433VAC 5A[AV5];
690VAC 5A[AV7]
±5% fs
Single /dual pulse,
open collector
Single/dual alarm
setpoint relay
Single/dual analogue
output
RS485 multidrop
birectional
3 digital inputs
Programming key-pad
[K]; RS232 Port [S]
18 to 60 VAC/DC [L]
90 to 260 VAC/DC [H]
CE - UL - CSA
See pag. 103
90 x 90 x 138
MODULAR
Power quality transducer.
32 bit µP based. Alarm
outputs, SMS messages.
Measurement of all
istantaneous variables.
Energy, water and gas
metering. 2MB memory+
Real time clock (on request).
240/415 VAC-1/5 AAC [AV5]
400/690 VAC-1/5 AAC [AV7]
class 0.5 (V-A)
10 samples /s
Up to 2 single/dual open
collector or relay modules
Up to 2 single/dual open
collector or relay modules
RS 422/485 port, RS232 port +
RTC+2MB data or RS232+RTC
Up to 6 digital inputs
Up to 2 single/dual
analog. output modules
18 to 60 VAC/DC [L]
90 to 260 VAC/DC [H]
CE
See pag. 103