35
Technical features
HF electromagnetic fields: < 1%
Influence of accessories: 0
■
Temperature drift
≤ 200ppm/°C
■
Sampling
1000 samples/s at 50Hz
■
Display
Type: Back-lighted LCD.
Display of instantaneous variables: 4x3 1/2 DGT.
Energies : Totals: 1x7 1/2 DGT; Partials: 1x7 1/2 DGT.
■
Maximum and minimum indication
Max. 1999 (19999999), Min. 0.
■
Measurements
Current, voltage, power, energy, power factor, frequency,
harmonic distortion (see display specifications).
TRMS measurement of distorted wave forms.
Coupling: direct.
■
Crest factor
Ib 5A : ≤3 (15A peak max.).
Ib 20A: ≤6 (127A peak max).
■
Current overload
5(10) A, for 10ms: 300 A max, at 50Hz
5(10) A, for 500ms: 200 A max, at 50Hz
5(10) A, permanent: 10A, at 50Hz
20(90) A, for 10ms: 2700A max, at 50Hz
20(90) A, permanent: 90A, at 50Hz
■
Voltage overload
Permanent: 1.2 Un.
For 1s: 2 Un.
5A connection