Specifications are subject to change without notice WM24-96DS0403 1
• Class 1 (active energy)
• Class 2 (reactive energy)
• Accuracy 0.5% RDG (current/voltage)
• Universal utility meter and power analyzer
• Backlighted LCD display
• Front size: 96x96 mm
•
Measurements of phase and system variables: W, W
dmd
, var,
VA, VA
dmd
, PF, V
L-N
, A, Hz
•
Measurements of total energies: kWh, kvarh C+/C-, kvarh L+/L-
•
Measurements of partial energies: kWh, kvarh C+/C-, kvarh L+/L-
•
Measurements according to EN61036 and EN61268
•
Time periods (t1, t2, t3, t4) management by means of input contacts
•
Measurements of m
3
H
2
O and m
3
GAS by means of input contacts
• TRMS measurement of distorted waves (currents/voltages)
• Universal power supply: 18-60VAC/VDC, 90-260 VAC/VDC
• Instantaneous variables read-out: 4x3 1/2 digit
• Energies, water, gas, variables read-out: 1x7 1/2 digit
• Protection degree (front): IP 65
Product Description
µP-based modular universal
utility meter and power ana-
lyzer with built-in program-
ming key-pad.
Particularly recommended for
the analysis of the electtrical
variables, for the multi time
periods (t1, t2, t3, t4) energy
metering and water/gas
metering. Housing for panel
mounting and IP65 (front)
protection degree.
Energy Management
Modular Universal Utility Meter and Power Analyzer
Type WM24-96
Type selection
Power supply
A: 24 VAC -15 +10%
50-60Hz
B: 48 VAC -15 +10%
50-60Hz
C: 115VAC -15 +10%
50-60Hz
D: 230 VAC -15 +10%
50-60Hz
L: 18 to 60VAC/VDC
H: 90 to 260VAC/VDC
Range code
AV4: 208VLL/1/5(6)AAC
-20% ≤ Un ≤+20%
AV5: 400VLL/1/5(6)AAC
-20% ≤ Un ≤+15%
AV6: 100VLL/1/5(6)AAC
-20% ≤ Un ≤+15%
AV7: 660VLL/1/5(6)AAC
-30% ≤ Un ≤+15%
50-60 Hz for all input mod-
ules. Module not removable.
• Up to 2 pulse outputs and up to 2 alarm outputs
• Up to 3 digital inputs for the time period and H
2
O and
GAS meters management
• MODBUS/JBUS (RTU) Protocol
• Optional RS232, RS422/485 serial ports
Slot C (redundant output or
digital inputs)
XX:
None
R1:
Single relay output
(AC1-8AAC, 250VAC)
R2: Dual relay output
(AC1-8AAC, 250VAC)
O1:
Single open collector
output (30V/100mADC)
O2:
Dual open collector
output (30V/100mADC)
D1:
3 digital inputs
D2:
3 digital inputs +
aux output
Options
X: None
S: RS232 serial port
Model
Range Code
System
Power Supply
Slot A
Slot B
Slot C
Slot D
Options
Ordering Key
WM24-96AV53H XX XX XX XX X
System
3: Three-phase,
unbalanced load,
with or without
neutral
Slot B (communication)
XX:
None
S1: Serial port,
RS485 multidrop,
bidirectional
Slot A
XX:
None
Slot D (alarm output)
XX:
None
R1:
Single relay output,
(AC1-8AAC, 250VAC)
R2: Dual relay output,
(AC1-8AAC, 250VAC)
O1: Single open collector
output
(30V/100mADC)
O2:
Dual open collector
output (30V/100mADC)
NOTE: max digital output (alarms and/or pulses): 2, any exceeding output is redundant.
NOTE: with the A, B, C, D types power supply, only an open collector module or a single relay output module can be
used. The instrument can be fully equipped only with L and H type power supply.
Comentarios a estos manuales