12
To instantly view a data sheet and specify products, visit www.GavazziOnline.com
Supply and Output Through Amplifier
2 Electrodes,
Hanging Probe
1 Electrode,
Hanging Probe
2 Electrodes 0.4 m
1 Electrode 0.5 m
2 Electrodes 0.5 m
3 Electrodes 0.5 m
1 Electrode 1 m
2 Electrodes 1 m
3 Electrodes 1 m
4 Electrodes 1 m
5 Electrodes 1 m
Ø 22 mmØ 18 mm 1" Ø 32 mm
VPx105
VPx205
VH1
A94-10
VPx310
VPx210
VPx110
VS2
VH2
Conductive Level Sensors
Amplifier
S194156
Sensing Distance
Housing Diameter, Dimension or Type
1
/
2
"
1
1
/
2
"
CLH3
VNxx2, VTx2
CLH5
VNxx4, VTx4
CLH5
CLH3
VNxx1, VTx1
CLH3
VNxx3, VTx3
SV11x
SV12x
SV21x
SV22x
CLDx
CLPx
Float Level Sensors
Horizontal
Mount
Vertical
Mount
17.5 mm
Polypropylene
Housing Material
ILMPU.5
FSH-x1
25 mm 28 mm 31 mm
ILMU.5
44 mm 45 mm
ILUx
50 mm
Nylon
FSH-x4
Polysulfone
FSH-x5
Stainless Steel
ILMM.5x
Polypropylene
ILSP.x,
ILMP.x
ILSP.x
Nylon
FSV-34
Polysulfone
FSV-35
Float Diameter
ILM.x
ILC
Mechanical float switches consisting of reed switch and enclosed magnet. Choice of housing materials include polypro-
pylene, nylon, polysulfone and stainless steel, to work with almost any liquid type. Vertical or horizontal mount types, to
allow access to any application. All of the float switches are pre-wired, to allow for quick and easy installation.
Conductive level sensing systems consist of a controller/relay and a probe
with multiple electrodes. Used for maximum/minimum control, in filling or
emptying applications. Can be used with virtually any type of conductive
liquid. Various housing materials are available, including nylon, PVC, Teflon,
and stainless steel, to cover many applications.
Comentarios a estos manuales