Available Modules
Measurement inputs: LSX, LSE, HSX, TRX
RS485 communication port: SX
RS232 communication port: SY
Analog output (*): AV
Relay and open collector outputs: R1, R2, R4, R5
Power supply: H, L
UDM35 / UDM40 USC
Slot A B C D A B C D E
Inputs/Outputs 1 2 3 4 1 2 3 4 5
(*) Note: A maximum of one analog output module
UDM35 base BD35
UDM40 base BD40
USC base BDXX
AC/DC inputs: 200µA, 2mA, 20mA, 200mV, 2V, 20V 1 BQLSX
AC/DC inputs: 200µA, 2mA, 20mA, 200mV, 2V, 20V + excitation output 1 BQLSE
AC/DC inputs: 200mA, 2A, 5A, 20V, 200V, 500V 1 BQHSX
Inputs: 20, 200, 2k,20k; TC: J-K-S-T-E, Pt100-250-500-1000, Ni100 1 BQTRX
Analog output: 0 to 20mA, 0 to 10V DC 1 BOAV
Relay output 1 BOR1
Relay output 2 BOR2
Outputs: 2 relays + 2 open collectors 4 BOR4
4 Relay output 4 BOR5
RS485 communication port 1 BRSX
RS232 communication port 1 BRSY
18 to 60V AC/DC power supply BPL
90 to 260V AC/DC power supply BPH
Type Output(s) UDM35 UDM40 USC Ordering Code
Specifications are subject to change without notice. 7
DPMbc2-9.qk 1/27/05 3:10 PM Page 7
Gross Automation (877) 268-3700 · www.carlogavazzisales.com · [email protected]